Tải xuống tài liệu () của 20
Chúng tôi tạo nên những điều quan trọng*

Rail rolling stock applications

xEffect MCBs & RCDs for rolling stock applications

 

Eaton’s xEffect range covers miniature circuit breakers (MCBs), residual current devices (RCDs) and related accessories that have proven themselves in numerous industrial applications around the world. To offer the highest degree of safety for passengers, personnel and equipment in rolling stock applications, the xEffect range is also certified in accordance with IEC 61373 and EN 45545.

IEC 61373
Rolling stock equipment - shock and vibration tests
EN 45545
Fire protection on railway vehicles
RT MCBs & RCDs
Suitable for ring cable lug connections

Protect your passengers and equipment

For operators and train manufacturers, safety is crucial. With our global xEffect MCB & RCD portfolio, we can help you to ensure energy efficiency, reliability and comfort with maximum safety for passengers and equipment.

Highly secure connections

Our xEffect portfolio contains a wide offering of RT MCBs and RCDs for ring cable lug connections. The use of ring cable lugs ensures an especially secure connection to address the demanding requirements for shock and vibration resistance in railway vehicles. Furthermore, we also offer devices featuring our highly secure Push-in terminal technology, for example the PXS24 electronic protection module.

Reliable protection for 24 V DC circuits

The tripping behavior of the PXS24 electronic protection module meets the particular needs of 24 V DC circuits, by providing reliable protection even in applications with long cables and high inrush currents.

Furthermore, the digital inputs and outputs allow for easy integration into your control system.

Rail-certified circuit breakers, protection modules and accessories

PXS24 Protection Module

PXS24 xEffect Electronic Protection Module

  • Overload & short circuit protection
  • Push-In terminals
  • In… up to 16 A
  • Un… 24 VDC
FAZ xEffect Miniature Circuit Breaker

FAZ xEffect Miniature Circuit Breaker

  • Overload & short circuit protection
  • In… up to 63 A
  • Un… up to 440 VAC; 60 VDC
  • Icu... up to 15kA
FAZ-NA-RT xEffect Miniature Circuit Breaker

FAZ-RT xEffect Miniature Circuit Breaker

  • Overload & short circuit protection
  • RT Types for ring cable lug connection
  • In… up to 63 A
  • Un… up to 440 VAC
  • Icu... up to 15kA
FAZ-PN xEffect Miniature Circuit Breaker

FAZ-PN xEffect Miniature Circuit Breaker

  • Overload & short circuit protection
  • 1+N MCBs in 1MU
  • In… up to 40 A
  • Un… up to 240 VAC
  • Icu… up to 10kA
FAZ-T xEffect Miniature Circuit Breaker 2-pol

FAZ-T xEffect Miniature Circuit Breaker

  • Overload & short circuit protection
  • In… up to 40 A
  • Un… up to 440 VAC; 60 VDC
  • Icu… up to 25kA
AZ xEffect Miniature Circuit Breaker

AZ xEffect Miniature Circuit Breaker

  • Overload & short circuit protection
  • In… up to 125 A
  • Un… up to 440 VAC; 60 VDC
  • Icu… up to 25kA
FAZ-DC xEffect Miniature Circuit Breaker

FAZ-DC/FAZ-RT-DC xEffect Miniature Circuit Breaker

  • Overload & short circuit protection
  • RT Types for ring cable lug connection
  • In… up to 50 A
  • Un… up to 500 VDC
  • Icu… up to 10kA
Eaton xEffect RCBO FRBm6 3+N-pole

xEffect Combined RCD/MCB Device, FRBm6/M, 1+N, 2, 3 and 3+N-pole

  • Residual current, overload & short circuit protection
  • RT Types for ring cable lug connection
  • In… up to 40 A
  • Un… up to 415 VAC
  • Icu… up to 15kA
Eaton xEffect RCBO FRBm4 3+N-pole

xEffect Combined RCD/MCB Device FRBm4 , 3+N-pole

  • Residual current, overload & short circuit protection
  • In… up to 32 A
  • Un… up to 415 VAC
  • Icu… up to 4,5kA
xEffect Residual Current Circuit Breaker FRCdM Type B, B+, Bfq

xEffect FRCdM Type B, Bfq and B+ Residual Current Circuit Breaker

  • Residual current protection
  • Real-time measurement of the residual current
  • Local pre-warning via LEDs
  • Remote pre-warning via potential free
  • output
  • In… up to 63 A
  • Un… up to 415 VAC
  • Icn… up to 10 kA with back-up fuse
xEffect Residual Current Circuit Breaker FRCdM Type AC, A, U, R

xEffect FRCdM Type A, U and R Residual Current Circuit Breaker

  • Residual current protection
  • Real-time measurement of the residual current
  • Local pre-warning via LEDs
  • Remote pre-warning via potential free
  • output
  • In… up to 63 A
  • Un… up to 415 VAC
  • Icn… up to 10 kA with back-up fuse
xEffect Residual Current Circuit Breaker FRCmM Type AC, A, U, R

xEffect FRCmM Type AC, A, U and R Residual Current Circuit Breaker

  • Residual current protection
  • RT Types for ring cable lug connection
  • In… up to 100 A
  • Un… up to 415 VAC
  • Icn… up to 10 kA with back-up fuse
xEffect Residual Current Circuit Breaker FRCmM Type F

xEffect FRCmM Type F Residual Current Circuit Breaker

  • Residual current protection
  • In… up to 100 A
  • Un… up to 415 VAC
  • Icn… up to 10 kA with back-up fuse
xEffect FBSmV add-on block

RCD Blocks FBSmV / FBHmV

  • Residual current protection
  • For the combination with FAZ or AZ MCBs
  • In… up to 125 A
  • Un… up to 415 VAC