Medium-voltage switchgear modernization and upgrades

Eaton's medium-voltage vacuum replacement circuit breakers are built brand new from the ground up to improve system reliability and provide technology upgrades. Eaton's portfolio includes vacuum replacement breakers, breaker to vacuum starter replacements and ground and test devices. The units are designed to be electrical and mechanical equivalents of the power circuit breakers they replace, with no parts reused from the original breakers. See our services brochure for more information.

Increased reliability
Extended life of switchgear
Industry leader
Vacuum interrupter technology
Robust
Built brand new from the ground up

Medium-voltage circuit breaker upgrade and replacement solutions

Medium-voltage vacuum replacement breakers

Solve parts availability problems, increase interrupting capability, reduce maintenance costs and downtime, and eliminate asbestos-filled arc chutes with VR Series+, VR Series, FAME and VHC+.

Medium-voltage breaker to vacuum starter replacements

Gain an efficient and cost-effective solution for electric utility generation and process industries that apply power circuit breakers as motor starters.

Medium-voltage ground and test devices

Apply temporary grounding to the phase conductors of switchgear during maintenance and testing in compliance with OSHA and NFPA 70E requirements.

VR-Series+ and VR-Series vacuum replacement circuit breakers

VR-Series+ and VR-Series vacuum replacement circuit breakers are designed to be electrical and mechanical equivalents of several different generations of the air-magnetic circuit breakers they replace including Westinghouse, Allis-Chalmers, Federal Pacific, General Electric, ITE, McGraw-Edison and more.
  • Resolve parts availability problems by utilizing common components
  • Reduce maintenance costs and downtime
  • Meets or exceeds IEEE/ANSI standards
  • 50% fewer parts reduces per breaker costs
  • Front accessible mechanism
  • Eaton's Sure-Close technology prevents circuit breaker from stalling during closing
  • Interrupting capabilities available in the same footprint, with bus bracing analysis
  • Eliminates asbestos arc-chutes with maintenance-free current transfer system and no contact maintenance
elem-vr-series-1500x1500.jpg

VHC-Series+ vertical to horiztonal conversion

Reduce maintenance and increase safety for GE Magne-Blast metal-clad switchgear with this reversible vertical-to-horizontal conversion that requires no cutting or drilling of the original vertical cell structure and does not violate the original metal-clad integrity.  

Watch this video to see the process and then click below to learn more on the VHC-Series+ conversion.

Factory Authorized Mechanism Enhancement (FAME)

Increase the life of Eaton’s medium-voltage VCP-W vacuum circuit breakers and MV-VR circuit breakers with the FAME upgrade, while also significantly reducing costs and ongoing maintenance requirements.

elem-fame-1500x1500.jpg

Medium-voltage breaker to vacuum starter replacements

mv-vsr-westinghouse-dhp-500x500.jpg

Eaton’s medium-voltage breaker to vacuum starter replacements offer an efficient and cost-effective solution for electric utility generation and process industries that apply power circuit breakers as motor starters. This combined power circuit breaker/vacuum contactor offers an optimal solution, with:

  • Draw-out capability
  • Ability to use the same cell interface components for levering and interlocking
  • Little to no cell modifications
  • Current limiting fuses as primary fault protection
  • Mechanically latched
  • Switching duty life of up to 250,000 operations
  • Compatibility and testing to IEEE/ANSI C37.59-2018

Medium-voltage ground and test devices

Eaton’s medium-voltage ground and test devices are used to apply temporary grounding to the phase conductors of switchgear during maintenance and testing of the equipment. With a draw out safety device that can be inserted into a circuit breaker cubicle in the same manner as the VR-Series, the ground and test devices are available as a single or dual terminal. 

  • Designed for insertion into the circuit breaker compartment to gain access to the primary stationary contacts or ground the circuit for maintenance work
  • Meets IEEE Std C27.20.6 2015
  • Ability to apply potential for cable testing
  • Enables access to both bus and line circuits for “phasing out” tests
  • Meets OSHA and NFPA 70E requirements
ground and test device

Remote power racking system (RPR-2.1)

Eaton’s RPR-2.1 enables remote racking of many manufacturers' low- and medium-voltage circuit breakers that can be inserted or removed using the rotation of a shaft. Operators may remain 25 feet or more away from the switchgear door during the racking process, which is outside of the arc flash protection boundary.

Preventive maintenance pays

It is widely documented that a well-designed, time-based preventive maintenance program can significantly reduce failure rates. Eaton’s predictive diagnostic services relies on the latest technologies to support a long-term predictive/preventive program to optimize equipment and uptime.

Optimize reliability through custom controls and panels

To ensure continuous uptime and business productivity, today’s electrical distribution and control systems require the highest level of protection against damaging power anomalies. But as these systems age, they face significant challenges, such as waning dependability, increased maintenance requirements and a lack of available spare parts ── all of which can compromise ongoing safety and reliability. Our UL508A certified custom panel shops in Warrendale, Penn., and Houston, Texas, provide engineering, design, and/or replacements ── made to your specifications.

Eaton’s engineering services team

Eaton’s engineering services team is dedicated to understanding your business so we can optimize your power system for safety, reliability and efficiency. As one of the largest and most experienced teams in the industry, we offer a comprehensive portfolio of services and solutions tailored for every stage of a power system’s life cycle. Eaton strives to create a zero-incident culture through the implementation of our safety policy including division safety managers and layered risk assessments. Our team has experience with electrical power distribution equipment from all leading manufacturers and stands ready to support you, 24/7, wherever and whenever you need us.
Specifications
Highlight differences
Show only differences
Hide blank features

Westinghouse Type DHP

Westinghouse Type DHP  Nominal kV Nominal MVA Amperes  
50DHP-VR+ / 50DHEP-VR+ * 4.16 75 / 250 / 250H  1200 / 2000 Westinghouse DHP circuit breaker
50DHP-VR 4.16 350 1200 / 2000 / 3000
75DHP-VR+ / 75DVP-VR+ * 7.2 500 1200 / 2000
75DHP-VR 7.2 500 / 500H 3000
150DHP-VR+ /150DVP-VR+ * 13.8 500 / 750 / 750H 1200 / 2000
150DHP-VR 13.8 750 / 1000 1200 / 2000 / 3000
*6 week lead time on quantity of 10 or less. Consult factory on lead time of quantity greater than 10.
 

Westinghouse Type DH

Westinghouse Type DH  Nominal kV Nominal MVA Amperes  
50DH-VR+ 4.16 250 1200 / 2000 Westinghouse DH circuit breaker
50DH-VR 4.16 350 1200 / 2000 / 3000
75DH-VR 7.2 500 1200 / 2000
150DH-VR+ 13.8 500 / 750 1200 / 2000
150DH-VR 13.8 1000 3000
 

General Electric Type AM - MagneBlast

General Electric Type AM - MagneBlast  Nominal kV Nominal MVA Amperes  
AM-2.4/4.16-VR+ 4.16 250 1200 / 2000 GE Type AM
AM-2.4/4.16-VR 4.16 350 1200 / 2000
AM-4.16-VR+ 4.16 250 1200 / 2000
AM-4.16-VR 4.16 350 1200 / 2000 / 3000
AM-5-VR+ 4.16 250 1200 / 2000
AMH-4.76-VR+ 4.16 250 1200 / 2000
AM-7.2-VR+ 7.2 500 1200 / 2000
AM-13.8-VR+ 13.8 500 / 750 1200 / 2000
AM-13.8-VR 13.8 1000 3000

General Electric Type VB1 PowerVac

General Electric Type VB1 PowerVac  Nominal kV Nominal MVA Amperes  
VB1-4.16-VR+ * 4.16 250 1200 / 2000 GE Type VB1
VB1-4.16-VR 4.16 350 1200 / 2000
VB1-7.2-VR+ * 7.2 500 1200 / 2000
VB1-13.8-VR+ * 13.8 500 / 750 1200 / 2000
*6 week lead time on quantity of 10 or less. Consult factory on lead time of quantity greater than 10.
 

Allis-Chalmers Type AM250, MA, F-Series

Allis-Chalmers Type AM250, MA, F-Series  Nominal kV Nominal MVA Amperes  
AM-VR+ 4.16 250 / 350 1200 / 2000 Allis-Chalmers Type AM250
MA-VR+ 4.16 250 1200 / 2000
MA-VR 4.16 350 1200 / 2000
MC-VR+ 13.8 500 1200
FA-VR 4.16 350 3000
FB-VR+ 7.2 500 1200 / 2000
FC-VR+ 13.8 500 / 750 1200 / 2000
FC-VR 13.8 1000 3000
 

Federal Pacific Electric Type DST

Federal Pacific Electric Type DST Nominal kV Nominal MVA Amperes  
DST-5-VR 4.16 250 / 350 1200 Federal pacific Type DST
DST-7.5-VR 7.2 500 1200 / 2000
DST-15-VR 13.8 500 / 750 / 1000 1200 / 2000

Federal Pacific Electric Type DST-2

Federal Pacific Electric Type DST-2 Nominal kV Nominal MVA Amperes  
DST-2-5-VR+ 4.16 250 1200 / 2000 Federal pacitic Type DST-2
DST-2-5-VR 4.16 350 1200 / 2000
DST-2-7.5-VR+ 7.2 500 1200 / 2000
DST-2-15-VR+ 13.8 500 / 750 1200 / 2000
 

ITE Type HK Model 03

ITE Type HK Model 03 Nominal kV Nominal MVA Amperes  
5HK-VR+ * 4.16 250 1200 / 2000 ITE Type HK
5HK-VR 4.16 350 1200 / 2000 / 3000
7.5HK-VR+ * 7.2 500 1200 / 2000
15HK-VR+ * 13.8 500 / 750 1200 / 2000
*6 week lead time on quantity of 10 or less. Consult factory on lead time of quantity greater than 10.
 

ITE Type VHK

ITE Type VHK Nominal kV Nominal MVA Amperes  
5VHK-VR+ * 4.16 250 1200 / 2000 ITE Type VHK
7.5VHK-VR+ * 7.2 500 1200 / 2000
15VHK-VR+ * 13.8 500 / 750 1200 / 2000
*6 week lead time on quantity of 10 or less. Consult factory on lead time of quantity greater than 10.

McGraw-Edison Type PSD and WSA

McGraw-Edison Type PSD and WSA Nominal kV Nominal MVA Amperes  
PSD-5-VR 4.16 250 / 350 1200 Mcgraw edison Type PSD and WSA
PSD-15-VR+ 13.8 500 / 750 1200 / 2000
WSA-5-VR 4.16 250 / 350 1200 / 2000
WSA-15-VR 13.8 500 / 750 1200 / 2000

Siemens Type 3AF

Siemens Type 3AF Nominal kV Nominal MVA Amperes  
5-3AF-VR+ 4.16 250 1200 / 2000

7-3AF-VR+ 7.2 500 1200 / 2000
15-3AF-VR+ 13.8 500 / 750 1200 / 2000